The Totalizer - Ampere Time Calculator
 
Model ATC-7000 

The ATC-7000 process controller provides exact, repeatable plating. This microprocessor-based instrument provides plating thickness control and a display of accumulated ampere-time.
 
The ATC-7000 is equipped with a battery back-up to maintain the totalizer memory in the event of a power interruption. In addition, the NEMA 4X The cabinet never needs to be opened as all settings are made from the front panel.
 
How it Works
 
Plating Thickness Control:
By presetting the number of ampere-minutes (or hours) desired using the touch panel, the unit will count down to zero and an alarm will sound.
 
Or, the ATC-7000 can be programmed to shut off the rectifier at the end of the plating cycle and restart it by presing "RESET".
 
Accumulated Ampere-Time:
At any time, the user can view accumulating ampere-time by pressing the "TOTALIZER" button.
 
System Setup:
By enetering tthe four digit numerical password, the user can clear the totalizer, calibrate for amp-minutes or amp-hours, or recalibrate the unit.
 
Specifications:
Accuracy:0.5% of set-point (1-100 Mv)
AC Input: 115V, 50/60 Hz
Ampere-time: Amp-miutes or hours
Dimensions: 6.25" L x 6.25" W x 4.25" H